KVGT issue

Started by Vetech6379 replies

  1. davecampbellNew Member#41

    I went and ran the machine with the DPF disconnected and it operated for about 10 min without throwing the code. Im going to clean the dpf tomorrow and see if i can get it back to work.

  2. John C.Super User#42

    The bucket is only run on one pump. If it is derating, you should have more than one code show up on the monitor.

  3. davecampbellNew Member#43

    Is it possible to use an ecm from a pc210-8 and eliminate this horribly complicated vgt system?

  4. max sNew Member#44

    No you can't, they are not the same model, you would have to change the engine harness and retrofit the connector that comes from the main harness to begin with, an extensive job that may not even work...

  5. IworkondiggersNew Member#45

    Ive diagnosed a few of these, as others have said check screens which you've done, oil pressure, once again done, my other propersition would be check epc command current and kvgt position sensor and see if they are working in correlation. Which if they have changed the kvgt assembly already probs not that. My other way to attack it is manually t into kvgt oil pressure, the control oil pressure at the turbo charger, I think I just remove the banjo bolt and had one tapped out to 1/8npt and and kvgt/EGR drive oil pressure and watch for drop outs. If you go right to the turbo and do the banjo bolt on the control side from the Epc check its fluctuations with the epc command current , (probs something in structure and function in shop manal for engine on how they correlate) This can help you find out if you have a failure in the EGR control valve side of things with possibly a failed epc or such, possibly try swapping them other if same part number

  6. davecampbellNew Member#46

    max s said: No you can't, Click to expand... bummer

  7. davecampbellNew Member#47

    Iworkondiggers said: Ive diagnosed a few of these, Click to expand... id like to start with simple first. do you know how much the kvgt shloud move? i get zero with machine shut doewn and .156 to .220 working it.

  8. Hoe handNew Member#48

    I have a 240lc-10 that is throwing lo3-ca2387 machine runs amazing for 30 minutes then throw code and derates. I have checked the screens on the egr inlet was a little dirty cleaned with brake cleaner and put back together and ran 5 minutes and same issue. Cleaned the 2 screens under the feed block ontop of the turbo still no change. Going to check pressures in the morning and go from their just trying to figure out if anybody ever figured out what their issue was any help is appreciated

  9. funwithfuelSenior Member#49

    Did you change the oil and filter when you serviced the screens?

  10. LACHAUJunior Member#50

    KVGT: Abbreviation for K omatsu V ariable G eometry T urbocharger and it is a variable displacement turbocharger.

  11. Hoe handNew Member#51

    funwithfuel said: Did you change the oil and filter when you serviced the screens? Click to expand... No I didn't probably should've but it has less than 100 hours on all new filters and fluids. The charge pump feeding the egr was putting out 210psi no fluctuations coming out of the egr valve

  12. DMillerSenior Member#52

    All these overcomplicated oversensitive pieces on vocational equipment, just insane.

  13. Welder DaveExpert#53

    Too bad you couldn't get a military spec. with all of it removed. It sounds worse than a nightmare.

  14. alexcNew Member#54

    hi guys does any of found what was the problem mine does the same issue as yours

  15. Hoe handNew Member#55

    Replaced turbo with brand new one and it threw CA2382 as soon as key was turned on and sent the turbo back thinking it could've been something in it and they came back and said their was nothing wrong with it after a month just put it back on today and it still throws CA2382 after keys on

  16. funwithfuelSenior Member#56

    First, did you remove, clean and inspect the screen at the EGR valve and did you verify good booster pump pressure? Did you start the machine and observe KVGT position while operating with and without load? Are you producing boost. The KVGT is hydraulically controlled. The computer has to see values within spec before the code can go inactive.

  17. LACHAUJunior Member#57

    CA 2382 says that the signal of position sensor of Komatsu Variable Geometry Turbocharger is low Voltage. First, check the wires; the wiring harness connector then check the position sensor... See the attached file for more details.

  18. Vetech63Senior Member#58

    LACHAU is getting fat on all that virtual steak I'm supplying him. Great info per usual!

  19. Hoe handNew Member#59

    funwithfuel said: First, did you remove, clean and inspect the screen at the EGR valve and did you verify good booster pump pressure? Did you start the machine and observe KVGT position while operating with and without load? Are you producing boost. The KVGT is hydraulically controlled. The computer has to see values within spec before the code can go inactive. Click to expand... Egr screens were removed and cleaned. Booster pressure was good and getting 4.97 volts to the kvgt sensor plug

  20. funwithfuelSenior Member#60

    Are there no other codes? Are you able to monitor voltage and position through the instrument panel? I think, I would want to monitor the voltage and position KOEO, and compare those values to KEOR, and then under load, so full throttle, arm in to end of travel and hit the boost button. (Left thumb button)