DieselDialogue

Deere 317G engine won't turn over

Started by kkcomp22 replies

  1. kkcompJunior Member#21

    Attempted Parked and Service cleaning 4 times with and without auto shutdown. Got a filter fault every time

  2. Mr. WrenchSenior Member#22

    kkcomp said: Attempted Parked and Service cleaning 4 times with and without auto shutdown. Got a filter fault every time Click to expand... What active faults do you have now? What were you attempting to do the regens with?

  3. kkcompJunior Member#23

    Current active faults are: 522577.11 3719.00 521197.04 520760.02 Stored also has: 2251.09 2000.09 1196.11 Service Menu -Exhaust -Soot HIGH Attempted Park clean from menu and it returns park clean not needed Attempted Service clean from menu with auto shutdown enabled. After 5 seconds it shut down then gave an error statement about the filter that went away before I could write it down. Could not repeat because machine will now turn over but not start.

Reply